﹡High precision,wide linearity range for output current
﹡Small size and elegant looking
﹡Mount directly to PCB
﹡A variety of configuration and output characteristics
﹡Used for electric metering
Product Origin:
Xiamen, ChinaHigh precision current transformer PCT216
Electrical SPEC
Rated Primary Current | 10A | ||||
Max Primary Current | 80A | ||||
Rated Secondary Current | 5mA | ||||
Accuracy | 0.1~2.0 | ||||
Electrical Strength | 3000VAC 1mA60s | ||||
Load Resistance | 20Ω | ||||
Rated Frequency | 50/60HZ |
Electrical Specification
Model No. |
Electrical Characteristics |
Dimension(Unit: mm/inch) |
Standard PN |
|||||||
Current Ratio |
RL(Ω) |
Accuracy Class |
||||||||
A |
B |
C |
D |
E |
F |
|||||
PCT207 |
10A(30)/10mA |
10 |
0.5 |
15.4 |
29.8 |
10.0 |
32.1 |
To be defined |
To be defined |
PCT207N100 |
20A(70)/10mA |
10 |
0.5,0.2 |
0.606 |
1.173 |
0.394 |
1.264 |
PCT207N200 |
|||
PCT210 |
10A(50)/10mA |
10 |
0.5,1 |
6.8 |
16.9 |
7.85 |
19.5 |
PCT210S100 |
||
5A(10)/5mA |
10 |
0.5,0.2 |
0.268 |
0.665 |
0.309 |
0.768 |
PCT210N100 |
|||
PCT216 |
20A(40)/20mA |
10 |
0.5,0.2 |
8.6 |
29.2 |
13.0 |
31.7 |
PCT216N100 |
||
50A(80)/25mA |
10 |
0.5,0.2 |
0.339 |
1.150 |
0.512 |
1.248 |
PCT216N200 |
|||
PCT225 |
20A(30)/20mA |
10 |
0.5,0.2 |
10.9 |
25.5 |
9.0 |
28.5 |
PCT225N100 |
||
50A(60)/25mA |
10 |
0.5,0.2 |
0.429 |
1.004 |
0.354 |
1.122 |
PCT225N200 |
|||
PCT226 |
20A(30)/20mA |
10 |
0.5,0.2 |
10.1 |
24.0 |
11.6 |
26.5 |
PCT226N100 |
||
50A(60)/25mA |
10 |
0.5,0.2 |
0.398 |
0.945 |
0.457 |
1.043 |
PCT226N200 |
|||
PCT233 |
20A(30)/10mA |
10 |
0.5,0.2 |
10.2 |
24.8 |
10.0 |
27.8 |
PCT233N200 |
||
30A(50)/10mA |
10 |
0.5,0.2 |
0.402 |
0.976 |
0.394 |
1.094 |
PCT233N300 |
|||
PCT234 |
20A(60)/10mA |
10 |
1,2 |
18.2 |
28.0 |
11.0 |
38.0 |
PCT234S200 |
||
30A(100)/10mA |
10 |
1,2 |
0.717 |
1.102 |
0.433 |
1.496 |
PCT234S300 |
|||
PCT235 |
10A(40)/10mA |
10 |
0.5,0.2 |
8.0 |
27.0 |
17.0 |
29.6 |
PCT235N100 |
||
50A(85)/25mA |
10 |
0.5,0.2 |
0.315 |
1.063 |
0.669 |
1.165 |
PCT235N200 |
|||
PCT236 |
10A(30)/10mA |
10 |
0.5,1 |
9.0 |
22.0 |
8.2 |
25.0 |
PCT236S100 |
||
20A(40)/8mA |
10 |
0.5,1 |
0.354 |
0.866 |
0.323 |
0.984 |
PCT236N250 |
|||
PCT237 |
20A(30)/10mA |
10 |
0.5,0.2 |
14.6 |
30.0 |
9.2 |
32.2 |
PCT237N200 |
||
50A(120)/25mA |
10 |
0.5,0.2 |
0.575 |
1.181 |
0.362 |
1.268 |
PCT237S200 |
|||
PCT245 |
10A(30)/10mA |
10 |
0.5,1 |
7.0 |
19.5 |
8.2 |
22.5 |
PCT245N100 |
||
20A(80)/10mA |
10 |
0.5,1 |
0.276 |
0.768 |
0.323 |
0.886 |
PCT245S200 |