ID 36mm split core current transformer
Steady in phase shift over the whole range
Small in size,clamp type,easy to use no need of cutting cable
Various of configuration and output characteristics
RoHS compliant, CE, ETL Certificate.
High accuracy Split core current transformer CT315
Frequency band: | 50Hz~60Hz | ||||||||||||
Dielectric strength: | 2000Vrms/1 MIN between Sec. / Pri. | ||||||||||||
Rated current: | 200A 50Hz | ||||||||||||
Max current: | 600A 50Hz | ||||||||||||
Rated load resistor: | 20Ω | ||||||||||||
Operate temperature | `-10~50℃ 0~80%RH | ||||||||||||
store temperature | `-30~80℃ 0~80%RH | ||||||||||||
Inductance | ≥15H (@50HZ,1V) | ||||||||||||
Max error(5A~200A) | Linearity error:1%(5A-600A) | ||||||||||||
Clamp times | ≥500 time |
Model No. |
Rated Input Current |
Rated Output |
Accuracy |
Dimension(Unit: mm/inch) |
|||||
Ф |
A |
B |
C |
D |
E |
||||
CT301 |
5-85A |
0-50mA |
0.5%~3% |
10 |
27.0 |
25.0 |
42.5 |
To be defined |
To be defined |
0.394 |
1.063 |
0.984 |
1.673 |
||||||
CT302 |
10-300A (10、50、100、200、250、300) |
0-200mA |
0.5%~3% |
24 |
46.0 |
34.0 |
66.0 |
||
0.945 |
1.811 |
1.339 |
2.598 |
||||||
CT303 |
5-180A |
0-100mA |
0.5%~3% |
16 |
33.0 |
31.5 |
43.5 |
||
0.630 |
1.299 |
1.240 |
1.713 |
||||||
CT304 |
5-30A |
0-30mA |
0.5%~3% |
6 |
26.4 |
16.0 |
32.0 |
||
0.236 |
1.039 |
0.630 |
1.260 |
||||||
CT305 |
10-630A(20、100、250、300、400、630) |
0-500mA |
0.5%~3% |
36 |
58.0 |
40.5 |
84.8 |
||
1.417 |
2.283 |
1.594 |
3.339 |
||||||
CT312 |
5-85A |
0-50mA |
0.5%~3% |
10 |
23.5 |
26.2 |
42.0 |
||
0.394 |
0.925 |
1.031 |
1.654 |
||||||
CT313 |
10-200A (10、50、100、200) |
0-200mA |
0.5%~3% |
16 |
30.5 |
31.0 |
45.2 |
||
0.630 |
1.201 |
1.220 |
1.780 |
||||||
CT314 |
10-300A (10、50、100、200、250、300) |
0-200mA |
0.5%~3% |
24 |
45.0 |
33.8 |
64.7 |
||
0.945 |
1.772 |
1.331 |
2.547 |
||||||
CT315 |
10-1000A(20 、100、250、300、400、630 800 1000) |
0-500mA |
0.5%~3% |
36 |
58.0 |
40.5 |
84.0 |
||
1.417 |
2.283 |
1.594 |
3.307 |
ZTC series of AC Split core current transformers are a simple to use, compact split-core design which is easily installed for metering applications. They are ideal for distributed measurement systems and can be retro-fitted into existing installations and non-interruptible equipment as there is no requirement for disconnection and re-connection of wiring.
Distribution Cabinet
We are providing customized service and expertise in consulting, design and manufacturing of current transformers, RCD fused connection unit and wireless energy monitor.