Products
Home

Electrical Safety

Current Transformer For GFCI

High quality Current transformer for GFCI ZG522

High quality Current transformer for GFCI ZG522

Current transformer for GFCI
* Compatible with UL943
* Precision and steady output characteristics;
* Close to zero load shift;
* Excellent characteristics in balance and temperature;
  • Product Detail

Current transformer for GFCI ZG522


The GFCI component must consist of ZCT and GNT coils. The ZCT coil is used to detect a small ground fault difference current between the live line and the earth line .The GNT coil is used to detect an over-current caused by arcing or short circuit of the cable fire or excessive current change. Current transformer is mainly used in GFCI sockets or plugs used in near-water environments such as kitchens, bathrooms, car washes, and arc fault breaker sockets or plugs for air conditioners.


Technical Specification:

Rated Current

20 A

DC Resistance at 25℃

ZCT
GNT

36±5Ω
9.2± 2Ω

Dielectric Withstanding   Voltage(Hi-pot)

 1500 V AC 1 min

Output Voltage Vo

ZCT
GNT

7.5-8.5mV
≥60mH


Specification & Dimension:

Model No.

Electrical Characteristics

Dimension(Unit:mm/inch)

Standard PN

Ip(A)

I(mA)

Rl(Ω)

ZCT:V(mV)

A

B

C

D

E

F

Pin

f(Hz)

u(V

GNT:Ls(mH)


523

20

5

1K

3.5-4.2

16

17.85

11.5

5

11

1.5

□0.64

Z/G523P100

1.0K

1.0V

90-140

0.630

0.703

0.453

0.197

0.433

0.059

0.025

524

20

5

1K

3.5-4.2

17.2

11

3.6

14

18.6

7

□0.64

Z/G524P100

1.0K

1.0V

90-140

0.677

0.433

0.142

0.551

0.732

0.276

0.025

530

30/50

5

1K

4.1±0.5

38.00

19.80

16.50

42.60

2.12

6.18

□0.64

Z/G530P100

1.0K

1.0V


100±25

1.496

0.780

0.650

1.677

0.083

0.243

0.025

537

20/30

5

1K

3.5-4.2

16

20.5

15.8

13.3

15.2

3.2

□0.64

Z/G537P100

1.0K

1.0V

90-140

0.630

0.807

0.622

0.524

0.598

0.126

0.025

542

20/30

5

1K

3.5-4.2

17.465

5.5

23.4

11.1

19.9

7.5

0.8

Z/G542P100

1.0K

1.0V

90-140

0.688

0.217

0.921

0.437

0.783

0.295

0.031

556

20

5

1K

3.5-4.2

16.9

5.21

10.5

3.18

6.36

17.4

□0.64

Z/G556P100

1.0K

1.0V

90-140

0.665

0.205

0.413

0.125

0.250

0.685

0.025


GFCI Current Transformer Application:      

√ Sensing toroid using to sense minimal differential current caused by the ground fault
√ Grounded neutral toroid using to sense unexpected excessive current change or overload current caused by the arc resulted from the fire or the short circuit

√ GFCI current transformer series are mainly applied to GFCI plugs, GFCI receptacles,connecting with various electric equipments, such as EV charger,Air-conditioner,Washing machine,Water heater, Car-washing equipment etc

√ Currently,our GFCI CTs are widely used for floor heating and HVAC controls.

√ And also these assemblies are applied to the AFCI used in the air-condition







Send A Message

Talk To ZTC Today To Discuss Your Need For Current Transformers,Get Standard Item, OEM/ODM Service Quote Are Available.
Related Products
3 phase current transformer

√ Precision and steady output √ Close to zero load shift √ Excellent balance characteristics √ Superior temperature stability

Current transformer for GFCI

Precision and steady output Close to zero load shift Excellent balance characteristics Superior temperature stability

current transformer company

Current transformer for GFCI * Compatible with UL943 * Precision and steady output characteristics; * Close to zero load shift; * Excellent characteristics in balance and temperature;

Current transformer for GFCI

Current transformer for GFCI * Compatible with UL943 * Precision and steady output characteristics; * Close to zero load shift; * Excellent characteristics in balance and temperature;

Smart meter Current transformer

Current transformer for GFCI * Compatible with UL943 * Precision and steady output characteristics; * Close to zero load shift; * Excellent characteristics in balance and temperature;

Current transformer for GFCI

Current transformer for GFCI, RCD Application * Compatible with UL943 * Precision and steady output characteristics * Close to zero load shift * Excellent characteristics in balance and temperature

Smart meter Current transformer

Current transformer for GFCI * Compatible with UL943 * Precision and steady output characteristics; * Close to zero load shift; * Excellent characteristics in balance and temperature;

Zero phase current transformer

High sensitivity and close to zero load shift Excellent characteristics in temperature and balance Small change of output voltage after large DC impulse A variety of configuration and output characteristics Used for leakage current detection

Read More
welcome to ZTC
Talk To ZTC Today To Discuss Your Need For Current Transformers,Get Standard Item, OEM/ODM Service Quote Are Available.

Home

Products

About

Contact