How to choose split core current transformer correctly?
Dec 17 , 2020
Current transformers can be divided into high voltage and low voltage, which are mainly distinguished by the highest voltage of the equipment. Generally, 10KV or more is high voltage, 10KV is medium voltage, and 1kv and below are low voltage. Split core current transformer is mainly used in low voltage, because SCT must be opened and closed, which makes SCT unable to carry out effective sealing an...
Read More
-
Let us learn about these kinds of inductors
Dec 17 , 2020
The inductor will have a blocking effect on the current passing through the inductor under the condition of alternating current. The higher the frequency of the inductor, the greater the blocking effect. This type of condition is called inductive reactance and is measured in ohms (Ω). Said. Inductor characteristic 2: The current passing through the inductor will not change suddenly, the current wi...
Read More
-
Be aware of these tips when using inductors
Feb 27 , 2021
The main uses of RF inductors are diverse, and can be used in various structural features to consider performance testing schemes for special applications. Matching, resonators and choke coils are the main common uses of inductors in RF power circuits. Matching includes removing the characteristic impedance mismatch and minimizing the reflective surface and loss of the middle route of power circui...
Read More
-
Analysis of the basic knowledge of these two current transformers and the difference between the two
Aug 12 , 2021
1. Bus-type current transformer and pillar-type current transformer Transformer I was asked a question by someone the day before, what is the difference between a bus-type current transformer and a pillar-type current transformer? At that time, there was some confusion, let alone the difference. I still don't have any idea what these two forms look like. After checking the materials, I found that ...
Read More
-
The magnitude of the transformer magnification is closely related to this power value
Aug 12 , 2021
The power of a three-phase meter is mainly determined by the current specification and model of the three-phase meter and the voltage required for on-site work. If it is a DC power meter, the power P=I current*U working voltage*3, let us give an example below. Transformer If the current specification and model of a three-phase meter is 40A and the working voltage on the spot is 380V, then the powe...
Read More
-
What is the relationship between light gas action and current transformer
Aug 12 , 2021
The safe operation and management of transformers is the focus of everyone’s daily work. Based on the experience exchange of abnormal operation conditions and common problems analysis of transformers, it will be helpful to immediately and accurately determine the causes and characteristics of common faults, and take immediate measures to ensure The safe operation of machinery and equipment. The va...
Read More
-
The higher the Q value, the lower the loss when winding the coil
Aug 12 , 2021
Let’s first talk about the definition of inductor quality factor Q Coil The Q value is the basic main parameter to consider the inductance. It refers to the ratio of the inductance exhibited by the inductance to its equivalent circuit loss resistance when the inductance works under a certain frequency of AC voltage. The higher the Q value of the inductor, the smaller its loss and the higher the ef...
Read More
-
Transformer internal structure transformation ratio conversion method
Mar 13 , 2022
The current transformer is an instrument and equipment that converts a large current on the primary side into a small current on the secondary side for accurate measurement according to the basic principle of the magnetic effect of current. It is mainly composed of a closed iron core and windings. Its primary side winding has a very small number of turns, which are connected in series in the route...
Read More