Products
Home

Electrical Safety

Ring Core

Nikel Core / Nickel Alloy Ring Core for GFCI & RCD

Nikel Core / Nickel Alloy Ring Core for GFCI & RCD

* High initial permeability and saturation magnetic induction.
* Excellent temperature stability.
* Supreme resistance against high current impulse.
* Lower core loss.
Permalloy core is widely used for zero phase current transformers and GFCI coils.
  • Product Detail

Nikel Core / Nickel Alloy Ring Core for GFCI & RCD Current Transformer


Widely used on Zero phase Current Transformer and GFCI current transformer


Dimensions Specification


Model No.

Type

Case Sizemm/inch)

Core Sizemm/inch)

Single Turn Performance

A

B

C

OD

ID

HT

Iin(1:1)mA

E(mV)

HP1201P

Laminated

7.6

13.45

3.16

12.2

8.8

0.35×5

25

>0.07

0.299

0.530

0.124

0.480

0.346

HP1201B

Laminated

8.23

14.36

3.1

12.2

8.8

0.35×5

25

>0.07

0.324

0.565

0.122

0.480

0.346

HP1201CB

Laminated

8.23

14.36

3.1

12.7

9.5

0.35×5

25

>0.07

0.324

0.565

0.122

0.500

0.374

HP1202P

Laminated

8.23

14.36

4.9

12.7

9.5

0.35×10

25

≥0.145

0.324

0.565

0.193

0.500

0.374

HP1301P

Laminated

8.8

14.9

3.27

13.4

9.8

0.35×5

25

>0.07

0.346

0.587

0.129

0.528

0.386

HP1302P

Laminated

9.8

14.7

3.6

13.5

11

0.35*7

25

0.06-0.09

0.386

0.579

0.142

0.531

0.433

HP1303C

Rolling

8.64

14.82

5.36

13.5

10

3.2

20

>0.2

0.340

0.583

0.211

0.531

0.394

0.126

HP1310C

Rolling

8.14

14.78

12.26

13

9

10

20

>0.06

0.320

0.582

0.483

0.512

0.354

0.394

HP1402P

Laminated

10.1

15.9

3.7

14.5

11.5

0.35*7

25

>0.07

0.398

0.626

0.146

0.571

0.453

HP1403P

Laminated

11.5

15.05

3.6

14.5

12.2

0.35*6

25

>0.05

0.453

0.593

0.142

0.571

0.480

HP1410C

Rolling

9.3

16

12.22

14.5

10

10

20

>0.6

0.366

0.630

0.481

0.571

0.394

0.394

HP1502C

Laminated

9.7

16.5

4.14

15

11

0.35×7

25

>0.065

0.382

0.650

0.163

0.591

0.433

HP1801P  

Laminated

11.6

19.3

3.25

17.5

13.2

0.35×5

25

>0.07

0.457

0.760

0.128

0.689

0.520

HP7704C

Laminated

61.6

79.5

7.4

77

64

0.35*11

25

>0.05

2.425

3.130

0.291

3.031

2.520 


Magnetic properties


Initial Permeability:80000 (Gs/Oe) min   /   Density:8.75 (g/cm3) 
Maximum Permeability:400000 (Gs/Oe)  /  Curie Temperature:400 (℃)
Saturated Induction density:0.75 (T) /  Saturated Magnetostrictive Coefficient :0.0005
Resistivity:0.56 (μΩ*m)  / Coercive Force:<0.006 (Oe)

Magnetic characteristics curve



Core Drawing


Testing Data




Production Process


Implement ISO9001 / 14000 / IATF16949 to meet electrical and electric manufacturing and automobile industry requirement.



Testing


A series incoming and outcoming inspection ensure our products have high quality to meet customers requirement and outcoming pass rate less then 10PPM.


Packing and Shipping



We are specialized in permalloy / Nickel Alloy ring cores for current transformers, providing customized service and expertise in consulting, design and manufacturing.


Contact us today to discuss your project!

Send A Message

Talk To ZTC Today To Discuss Your Need For Current Transformers,Get Standard Item, OEM/ODM Service Quote Are Available.
Related Products
magnetic ring toroidal core,Permalloy Ring Core for GFCI & RCD

* High initial permeability and saturation magnetic induction. * Excellent temperature stability. * Supreme resistance against high current impulse. * Lower core loss. Permalloy core is widely used for zero phase current transformers and GFCI coils.

magnetic ring toroidal core,Permalloy Ring Core for GFCI & RCD

* High initial permeability and saturation magnetic induction. * Excellent temperature stability. * Supreme resistance against high current impulse. * Lower core loss. Permalloy core is widely used for zero phase current transformers and GFCI coils.

magnetic ring toroidal core,Permalloy Ring Core for GFCI & RCD

* High initial permeability and saturation magnetic induction. * Excellent temperature stability. * Supreme resistance against high current impulse. * Lower core loss. Permalloy core is widely used for zero phase current transformers and GFCI coils.

Zero phase current transformer

High sensitivity and close to zero load shift Excellent characteristics in temperature and balance Small change of output voltage after large DC impulse A variety of configuration and output characteristics Used for leakage current detection

zero phase sequence

High sensitivity and close to zero load shift Excellent characteristics in temperature and balance Small change of output voltage after large DC impulse A variety of configuration and output characteristics Used for leakage current detection

toroidal current transformer

High sensitivity and close to zero load shift Excellent characteristics in temperature and balance Small change of output voltage after large DC impulse A variety of configuration and output characteristics Used for leakage current detection

Zero phase current transformer

High sensitivity and close to zero load shift Excellent characteristics in temperature and balance Small change of output voltage after large DC impulse A variety of configuration and output characteristics Used for leakage current detection

miniature precision current transformer

﹡High precision,wide linearity range for output current ; ﹡Small size and elegant looking ; ﹡Mount directly to PCB; ﹡A variety of configuration and output characteristics; ﹡Used for electric metering;

Read More
welcome to ZTC
Talk To ZTC Today To Discuss Your Need For Current Transformers,Get Standard Item, OEM/ODM Service Quote Are Available.

Home

Products

About

Contact